{"id":31966,"date":"2022-06-03T15:29:25","date_gmt":"2022-06-03T13:29:25","guid":{"rendered":"https:\/\/www.yamawa.eu\/the-use-of-taps-with-coolant-holes\/"},"modified":"2024-09-14T16:53:42","modified_gmt":"2024-09-14T14:53:42","slug":"the-use-of-taps-with-coolant-holes","status":"publish","type":"post","link":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/","title":{"rendered":"The use of taps with coolant holes"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\" class=\"lead\">This article deals with the most important factors to consider when using <strong>taps with internal coolant holes<\/strong>: the <strong>filtration system<\/strong> and <strong>coolant discharge pressure<\/strong> that need to be carefully configured to achieve the best performances of the process.<\/p>\n\n<h2 class=\"wp-block-heading\">Keep an eye on the filtration system<\/h2>\n\n<p class=\"wp-block-paragraph\">When using a tap with coolant holes, Yamawa recommends to always maintaining a <strong>high degree of filtration<\/strong> to ensure the removal of any dust and chips. Check the built-in filter of your machine: a mesh of <strong>20~50 \u03bcm<\/strong> should be used.<br\/>Sludge or fine chips may be stuck in the tap&#8217;s coolant holes, clogging the holes and reducing the coolant flow. When the amount of coolant supply decreases, a tap breakage may occur. To avoid clogging, timely replace the coolant filters to maintain the filtration accuracy below 100 \u03bcm.<\/p>\n\n<h2 class=\"wp-block-heading\">The role of discharge pressure<\/h2>\n\n<p class=\"wp-block-paragraph\">The level of coolant pressure depends on tapping conditions. The coolant pump must<strong> supply enough coolant<\/strong> to the cutting edge chamfer of the tap and &#8211; if needed &#8211; it must be able to <strong>forcibly discharge the chips<\/strong>. In some cases, the use of a higher coolant pressure may be required.<\/p>\n\n<p class=\"wp-block-paragraph\">According to Yamawa\u2019s best practices, tapping achieves the maximum benefits when using the higher coolant discharge pressure. Be aware that the coolant discharge <strong>pressure limit<\/strong> for a standard tapping holder is <strong>6.5~7<\/strong> MPa.<\/p>\n\n<p class=\"wp-block-paragraph\">The coolant discharge pressure of a CNC machine is usually an optional setting at the time of purchase. Herein some reference values:<\/p>\n\n<ul class=\"wp-block-list\"><li>Around 1.5 MPa \u2013 basic\/standard coolant pressure specification<\/li><li>Around 3 MPa &#8211; high coolant pressure specification<\/li><li>Around 7 MPa &#8211; super-high coolant pressure specification<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">To sum up, here there are your <strong>practical tips<\/strong> when using taps with coolant holes:<\/p>\n\n<ul class=\"wp-block-list\"><li>Use filters with a mesh of 20~50 \u03bcm.<\/li><li>Regularly replace filters<\/li><li>Keep coolant discharge pressure around 1.5~3 MPa<\/li><li>Consider using <strong><\/strong> such as <strong>HT<\/strong>, <strong>SP<\/strong>, <strong>PO<\/strong> taps with <strong>specific flute design<\/strong> that facilitate chip evacuation.<\/li><\/ul>\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button aligncenter\"><a class=\"wp-block-button__link has-background\" href=\"https:\/\/www.yamawa.eu\/ee\/category\/tech_tips-ee\/\" style=\"border-radius:2px;background-color:#3fa535\"><strong>READ MORE TECH TIPS<\/strong><\/a><\/div>\n<\/div>\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This article deals with the most important factors to consider when using taps with internal coolant holes: the filtration system and coolant discharge pressure that need to be carefully configured to achieve the best performances of the process. Keep an eye on the filtration system When using a tap with coolant holes, Yamawa recommends to&#8230;  <a href=\"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/\" class=\"more-link\" title=\"Read The use of taps with coolant holes\">Read more &raquo;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1502],"tags":[1521,1522,1523,1524,1525,1506],"class_list":["post-31966","post","type-post","status-publish","format-standard","hentry","category-tech_tips-ee","tag-coolant-ee","tag-coolant-holes-ee","tag-ht-taps-ee","tag-po-taps-ee","tag-sp-taps-ee","tag-tech-tips-ee"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>The use of taps with coolant holes - Yamawa<\/title>\n<meta name=\"description\" content=\"Learn how to effectively configure the filtration system and coolant discharge pressure when using taps with internal coolant holes.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The use of taps with coolant holes - Yamawa\" \/>\n<meta property=\"og:description\" content=\"Learn how to effectively configure the filtration system and coolant discharge pressure when using taps with internal coolant holes.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/\" \/>\n<meta property=\"og:site_name\" content=\"Yamawa\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-03T13:29:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-14T14:53:42+00:00\" \/>\n<meta name=\"author\" content=\"Editor Yamawa\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Editor Yamawa\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/the-use-of-taps-with-coolant-holes\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/the-use-of-taps-with-coolant-holes\\\/\"},\"author\":{\"name\":\"Editor Yamawa\",\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/#\\\/schema\\\/person\\\/4fc496cd5e6764d4e909fae0ea2933c7\"},\"headline\":\"The use of taps with coolant holes\",\"datePublished\":\"2022-06-03T13:29:25+00:00\",\"dateModified\":\"2024-09-14T14:53:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/the-use-of-taps-with-coolant-holes\\\/\"},\"wordCount\":323,\"publisher\":{\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/#organization\"},\"keywords\":[\"coolant\",\"coolant holes\",\"HT Taps\",\"PO taps\",\"SP taps\",\"tech tips\"],\"articleSection\":[\"Tech Tips\"],\"inLanguage\":\"ee-EE\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/the-use-of-taps-with-coolant-holes\\\/\",\"url\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/the-use-of-taps-with-coolant-holes\\\/\",\"name\":\"The use of taps with coolant holes - Yamawa\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/#website\"},\"datePublished\":\"2022-06-03T13:29:25+00:00\",\"dateModified\":\"2024-09-14T14:53:42+00:00\",\"description\":\"Learn how to effectively configure the filtration system and coolant discharge pressure when using taps with internal coolant holes.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/the-use-of-taps-with-coolant-holes\\\/#breadcrumb\"},\"inLanguage\":\"ee-EE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/the-use-of-taps-with-coolant-holes\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/the-use-of-taps-with-coolant-holes\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/avaleht\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The use of taps with coolant holes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/#website\",\"url\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/\",\"name\":\"Yamawa\",\"description\":\"The world leader on Threading Tools for 90 years\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ee-EE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/#organization\",\"name\":\"Yamawa\",\"url\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ee-EE\",\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.yamawa.eu\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/cropped-logo_yamawa.png\",\"contentUrl\":\"https:\\\/\\\/www.yamawa.eu\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/cropped-logo_yamawa.png\",\"width\":489,\"height\":103,\"caption\":\"Yamawa\"},\"image\":{\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/#\\\/schema\\\/person\\\/4fc496cd5e6764d4e909fae0ea2933c7\",\"name\":\"Editor Yamawa\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ee-EE\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2be56baa0c7c43e6891985b4d129acaa2d858e7ee9e27b404536298582901f8b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2be56baa0c7c43e6891985b4d129acaa2d858e7ee9e27b404536298582901f8b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2be56baa0c7c43e6891985b4d129acaa2d858e7ee9e27b404536298582901f8b?s=96&d=mm&r=g\",\"caption\":\"Editor Yamawa\"},\"url\":\"https:\\\/\\\/www.yamawa.eu\\\/ee\\\/author\\\/yamawa-admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"The use of taps with coolant holes - Yamawa","description":"Learn how to effectively configure the filtration system and coolant discharge pressure when using taps with internal coolant holes.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/","og_locale":"en_US","og_type":"article","og_title":"The use of taps with coolant holes - Yamawa","og_description":"Learn how to effectively configure the filtration system and coolant discharge pressure when using taps with internal coolant holes.","og_url":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/","og_site_name":"Yamawa","article_published_time":"2022-06-03T13:29:25+00:00","article_modified_time":"2024-09-14T14:53:42+00:00","author":"Editor Yamawa","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Editor Yamawa","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/#article","isPartOf":{"@id":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/"},"author":{"name":"Editor Yamawa","@id":"https:\/\/www.yamawa.eu\/ee\/#\/schema\/person\/4fc496cd5e6764d4e909fae0ea2933c7"},"headline":"The use of taps with coolant holes","datePublished":"2022-06-03T13:29:25+00:00","dateModified":"2024-09-14T14:53:42+00:00","mainEntityOfPage":{"@id":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/"},"wordCount":323,"publisher":{"@id":"https:\/\/www.yamawa.eu\/ee\/#organization"},"keywords":["coolant","coolant holes","HT Taps","PO taps","SP taps","tech tips"],"articleSection":["Tech Tips"],"inLanguage":"ee-EE"},{"@type":"WebPage","@id":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/","url":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/","name":"The use of taps with coolant holes - Yamawa","isPartOf":{"@id":"https:\/\/www.yamawa.eu\/ee\/#website"},"datePublished":"2022-06-03T13:29:25+00:00","dateModified":"2024-09-14T14:53:42+00:00","description":"Learn how to effectively configure the filtration system and coolant discharge pressure when using taps with internal coolant holes.","breadcrumb":{"@id":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/#breadcrumb"},"inLanguage":"ee-EE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.yamawa.eu\/ee\/the-use-of-taps-with-coolant-holes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.yamawa.eu\/ee\/avaleht\/"},{"@type":"ListItem","position":2,"name":"The use of taps with coolant holes"}]},{"@type":"WebSite","@id":"https:\/\/www.yamawa.eu\/ee\/#website","url":"https:\/\/www.yamawa.eu\/ee\/","name":"Yamawa","description":"The world leader on Threading Tools for 90 years","publisher":{"@id":"https:\/\/www.yamawa.eu\/ee\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.yamawa.eu\/ee\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ee-EE"},{"@type":"Organization","@id":"https:\/\/www.yamawa.eu\/ee\/#organization","name":"Yamawa","url":"https:\/\/www.yamawa.eu\/ee\/","logo":{"@type":"ImageObject","inLanguage":"ee-EE","@id":"https:\/\/www.yamawa.eu\/ee\/#\/schema\/logo\/image\/","url":"https:\/\/www.yamawa.eu\/wp-content\/uploads\/2017\/04\/cropped-logo_yamawa.png","contentUrl":"https:\/\/www.yamawa.eu\/wp-content\/uploads\/2017\/04\/cropped-logo_yamawa.png","width":489,"height":103,"caption":"Yamawa"},"image":{"@id":"https:\/\/www.yamawa.eu\/ee\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.yamawa.eu\/ee\/#\/schema\/person\/4fc496cd5e6764d4e909fae0ea2933c7","name":"Editor Yamawa","image":{"@type":"ImageObject","inLanguage":"ee-EE","@id":"https:\/\/secure.gravatar.com\/avatar\/2be56baa0c7c43e6891985b4d129acaa2d858e7ee9e27b404536298582901f8b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2be56baa0c7c43e6891985b4d129acaa2d858e7ee9e27b404536298582901f8b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2be56baa0c7c43e6891985b4d129acaa2d858e7ee9e27b404536298582901f8b?s=96&d=mm&r=g","caption":"Editor Yamawa"},"url":"https:\/\/www.yamawa.eu\/ee\/author\/yamawa-admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/posts\/31966","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/comments?post=31966"}],"version-history":[{"count":1,"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/posts\/31966\/revisions"}],"predecessor-version":[{"id":32138,"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/posts\/31966\/revisions\/32138"}],"wp:attachment":[{"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/media?parent=31966"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/categories?post=31966"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.yamawa.eu\/ee\/wp-json\/wp\/v2\/tags?post=31966"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}